    Technical Specifications

    UA-Hub-Door
    Mechanical
    Dimensions 174.9 x 126 x 32.9 mm (6.9 x 5 x 1.3")
    Weight 363 g (12.8 oz)
    Enclosure material Polycarbonate
    Mounting material Polycarbonate
    Hardware
    Networking interface (5) 10/100/1000 Base-T
    Power method PoE++
    UL 294 Power-limited Class 2 PSU
    UL 60950/62368 LPS/PS2 PSU
    Max. power consumption Without PoE output: 30W
    With PoE output: 50W
    PoE input 50V DC, 1A
    PoE output PoE passthrough, (4) PoE, 50V DC, total 20W
    Button (1) Factory-reset
    LEDs System: white/blue
    Output relays: white
    Digital input Request to exit/request to enter/remote release/door position sensor
    Dry output relay Lock: 30V DC, 1A
    Aux: 30V DC, 1A
    Powered output relay Lock: 12V DC, 1A
    Aux: 12V DC, 0.33A
    12V DC, 0.33A
    Operating environment Indoor use only
    Ambient operating temperature 0 to 40° C (32 to 104° F) 
    Ambient operating humidity 5 to 95% noncondensing
    UL 294 level Destructive attack: Level I
    Line security:  Level I
    Endurance: Level I
    Standby power: Level I
    UL 294 statement Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL 294.
    The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
    CAN/ULC-60839-11-1 Grade Grade assignment: 1
    Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
    Document number, and issue date and/or revision level UA-Hub-Door002, V01
    Wiring Information
    Wiring gauge requirements (AWG)
    Total length to device Output load current at 12V DC
    100mA 250mA 500mA 1A       
    6.1 m (20 ft) 22 22 22 18
    15.2 m (50 ft) 22 22 22 18
    30.5 m (100 ft) 22 22 18 18

    UACC-Cable-DoorLockRelay (18 AWG) is recommended.
    PoE cabling requirements The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 24 AWG (0.21 mm2) for horizontal or riser cable.
    LEDs
    PoE in Steady blue: Adopted/device is ready
    Steady white: Pending adoption
    Blinking white/blue: Upgrading firmware
    PoE out Off: Not connected or no data link
    Steady blue: Connected and data link on
    UA-G2-Pro
    Mechanical
    Dimensions 160 x 40.4 x 40.55 mm (6.3 x 1.59 x 1.6")
    Weight 136 g (4.8 oz)
    Enclosure material Polycarbonate, glass
    Mount material Aluminum alloy
    Mounting Wall, gang box
    Weatherproofing IP55
    Hardware
    Networking interface (1) GbE RJ45 port
    Connectivity BLE 4.2
    NFC
    Power method PoE
    UL 294 Power-limited Class 2 PSU
    UL 60950-1/62368-1 LPS/PS2 PSU
    Supported voltage range 48V DC
    Max. power consumption 6W
    ESD/EMP protection Air: ±15kV, contact: ±8kV
    Sensor Proximity sensor
    Camera 4000 x 3000, 12 MP, 30 FPS
    Microphone Yes
    Speaker (1) 4 ohm, 1.5W
    LEDs R/G/B/W
    Flash
    Button (1) Factory-reset
    NFC frequency 13.56 MHz
    NFC read range < 30 mm
    NFC standards ISO 14443A, 14443B, 15693
    NFC technology NFC Tag 1,2,3,4,5
    MIFARE Classic
    MIFAREPlus
    MIFARE Ultralight
    MIFARE DESFire
    Operating environment Outdoor use
    Ambient operating temperature Device: -30 to 45° C (-22 to 113° F)
    Display:* -10 to 45° C (14 to 113° F)
    *The display will turn off when the ambient temperature is above/below the display operation temperature, but other functions will remain functional. (Effective after firmware v1.3.28)
    Ambient operating humidity 5 to 90% noncondensing
    Software information The software version of a product can be checked at https://unifi.ui.com
    UL 294 level Destructive attack: Level I
    Line security: Level I
    Endurance: Level I
    Standby power: Level I
    UL 294 statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
    The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
    PoE cabling requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
    The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
    CAN/ULC-60839-11-1 Grade Grade assignment: I
    Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
    Document number, and issue date and/or revision level UA-G2-Pro/UA-G2-Pro-Black, V02
    LED
    System Steady blue: Adopted/device is ready
    Steady white: Pending adoption
    Blinking white/blue: Upgrading firmware
    Strobing red: Emergency lockdown
    UA-G2
    Mechanical
    Dimensions 93 x 40 x 36.5 mm (3.7 x 1.6 x 1.4")
    Weight 82 g (2.9 oz)
    Enclosure material Polycarbonate, glass
    Mounting In wall, gang box
    Weatherproofing IP55
    Hardware
    Networking interface (1) 10/100 MbE RJ45 port
    Connectivity BLE 4.1
    Power method PoE
    UL 294 Power-limited Class 2 PSU
    UL 60950-1/62368-1 LPS/PS2 PSU
    Supported voltage range 48V DC
    Max. power consumption 5W
    ESD/EMP protection Air: ±15kV, contact: ±8kV
    Sensors Proximity sensor
    Speaker (1) 8 ohm, 0.7W
    LEDs R/G/B/W
    Button (1) Factory-reset
    NFC frequency 13.56 MHz
    NFC read range < 30 mm
    NFC standards ISO 14443A, 14443B, 15693
    NFC technology NFC Tag 1,2,3,4,5
    MIFARE Classic
    MIFAREPlus
    MIFARE Ultralight
    MIFARE DESFire
    Operating environment Outdoor use
    Ambient operating temperature -30 to 45° C (-22 to 113° F)
    Ambient operating humidity 5 to 90% noncondensing
    Software information The software version of a product can be checked at https://unifi.ui.com
    UL 294 level Destructive attack: Level I
    Line security: Level I
    Endurance: Level I
    Standby power: Level I
    UL 294 statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
    The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
    PoE cabling requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
    The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
    CAN/ULC-60839-11-1 Grade Grade assignment: I
    Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
    Document number, and issue date and/or revision level UA-G2/UA-G2-Black, V02
    LED
    System Steady blue: Adopted/device is ready
    Steady white: Pending adoption
    Blinking white/blue: Upgrading firmware
    Strobing red: Emergency lockdown
    UA-Pocket
    Mechanical
    Dimensions 84 x 39 x 7.4 mm (3.3 x 1.5 x 0.29")
    Weight 16 g (0.56 oz)
    Enclosure material Polycarbonate, stainless steel
    Weatherproofing IP54
    Hardware
    NFC frequency 13.56 MHz
    NFC technology ISO/IEC 14443 Type A
    MIFARE DESFire EV3 4K
    UniFi Access Proprietary Security Protocol
    Ambient operating temperature -10 to 45° C (14 to 113° F)
    Ambient operating humidity 10 to 90% noncondensing
    Certification CE